Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery
2018
Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes …
Changes in the anterior chamber during accommodation assessed with a Scheimpflug system.
2014
Purpose To study changes in the anterior chamber depth (ACD), anterior chamber angle, and pupil diameter with accommodation. Setting University of Valencia, Valencia, Spain. Design Evaluation of diagnostic technology. Methods A rotating Scheimpflug camera (Pentacam HR) was used to measure changes in the ACD, anterior chamber angle, and pupil diameter with accommodation. Peripheral ACD was measured at the corneal center and 2.0 mm away from it in the nasal, superior, temporal, and inferior directions. The anterior chamber angle was computed as the mean anterior chamber angle of the entire eye. All measurements were obtained with accommodation stimuli ranging from +1.0 to −4.0 diopters (D) in…
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.
2014
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…
Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review
2016
We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…